In February, the FDA published the second revision of their Guidance for Industry "Microbiology Data for Systemic Antibacterial Drugs -Development, Analysis, and Presentation". The focus of that guidance document is on assisting sponsors in the development, analysis, and presentation of microbiology data during antibacterial drug development. It replaces the guidance for industry "Microbiology Data for Systemic Antibacterial Drugs - Development, Analysis, and Presentation" issued in August 2016.
In the document the FDA defines their expectation on a microbiology development programme needed to support clinical development and approval of antibacterial drugs administered systemically as well as microbiology information collected after approval.
The current guideline covers the following topics:
I. INTRODUCTION
II. MICROBIOLOGY DEVELOPMENT PROGRAM
A. Early Development Nonclinical Considerations
1. Antibacterial Spectrum of Activity
2. Mechanism of Action
3. Intracellular Antimicrobial Concentration Assessment
4. Resistance Studies
B. In Vitro Antimicrobial Susceptibility Test Methods During Drug Development
1. Early Clinical Development
2. Provisional Antibacterial Susceptibility Test Interpretive Criteria
3. Establishing In Vitro Antibacterial Susceptibility Test Interpretive Criteria
4. Quality Control Parameters
C. Other Considerations
1. First and Second Lists of Target Bacteria in Labeling
2. Antibacterial Interactions and Fixed-Combination Studies
3. Additional Nonclinical Studies of Antibacterial Drugs
4. Animal Models of Infection
5. Microbiology Information Collected in Clinical Trials
6. Electronic Submission of Microbiology Information
7. Location of Microbiology Information
8. Postmarketing Microbiology Information
Additionally the following appendizes are part of the revised guideline:
APPENDIX A: GUIDELINES FOR BACTERIAL ISOLATE SELECTION FOR STUDIES OF IN VITRO ANTIBACTERIAL ACTIVITY
APPENDIX B: STUDY REPORTS OF SPECTRUM OF ACTIVITY AND RESISTANCE
APPENDIX C: DATABASE FOR FINAL IN VITRO ANTIBACTERIAL SUSCEPTIBILITY TEST INTERPRETIVE CRITERIA
APPENDIX D: EXAMPLE FORMAT FOR SECTIONS OF LABELING THAT PERTAIN TO MICROBIOLOGY
APPENDIX E: INFORMATION REGARDING THE SECOND BACTERIA LIST IN THE MICROBIOLOGY SUBSECTION OF LABELING
This guidance addresses the types of microbiology information that should be provided to support an investigational new drug application (IND), a new drug application (INDA), a biologics license application (BLA), and a supplemental NDA or BLA. For more details see the full document "Microbiology Data for Systemic Antibacterial Drugs"
Biologic and Biosimilar Misinformation: FDA Drafts Guidance
Since at least 2018, various industry groups and biopharma companies have highlighted the ways that the truth has been stretched around biosimilars and their reference products, and they have sought help from the US Food and Drug Administration (FDA) in setting the record straight.
FDA on Monday offered some help in the way of a new draft guidance, with eight questions and answers explaining how companies can promote reference or biosimilar products in truthful and non-misleading ways. But the agency did not single out specific violations or point to real world examples of misinformation.
“Although assessment of each promotional presentation involves a fact specific determination, representations or suggestions that create an impression that there are clinically meaningful differences between the reference product and its biosimilar, such as promotional presentations representing or suggesting that a reference product is safer or more effective than its biosimilar product, or that a biosimilar is safer or more effective than its reference product are likely to be false or misleading. Similarly, representations or suggestions that create an impression that a biosimilar is not highly similar to its reference product are likely to be false or misleading,” the 10-page draft guidance says.
Similarly, FDA says that companies claiming that a biosimilar is in general less safe or less effective than the reference product “simply because the biosimilar is licensed for fewer indications than the reference product would be misleading.”
Misleading comments were highlighted by Pfizer in August 2018, when it filed a citizen petition with FDA asking for help to combat comments that leave out important details about what a biosimilar is or that biosimilars work in the same way as reference products.
And Monday’s draft does reiterate that licensed biosimilars have “been found to be highly similar to the reference product notwithstanding minor differences in clinically inactive components and that there are no clinically meaningful differences between the biosimilar and the reference product in terms of safety, purity, and potency.” But the draft also does not discuss considerations unique to promotional materials for interchangeable biosimilars.
Novartis similarly raised issues with FDA in November 2018 about companies that seek “to foster fear and highlight hypothetical yet unproven risks associated with the use of FDA-approved biosimilars.” The Biosimilars Forum and others also sought to extinguish the ideas that biosimilars are somehow inferior products if they are not approved as interchangeable biosimilars, or to explain how the term “non-medical switching” is used “disingenuously to claim that transitioning from an originator to a biosimilar medicine is not safe.”
FDA’s draft also offers two examples of when it would not object to the promotions described, in addition to one example that would be considered misleading.
The misleading example discusses a statement that accurately conveys the reference product’s higher numeric overall response rates observed in a study, but that does not disclose that this difference in response rates was not statistically significant, and which fails to describe the study design or include other appropriate context.
In addition to the draft guidance, FDA and the Federal Trade Commission (FTC) also announced a public workshop on 9 March to discuss biosimilar competition.
The agencies said they will continue to exchange information about best practices to ensure biosimilar developers can gain access to samples of the reference product. The FTC also said it intends to review patent settlement agreements involving biosimilars to prevent antitrust violations.
Promotional Labeling and Advertising Considerations for Prescription Biological Reference and Biosimilar Products Questions and Answers Guidance for Industry
FDA on Monday offered some help in the way of a new draft guidance, with eight questions and answers explaining how companies can promote reference or biosimilar products in truthful and non-misleading ways. But the agency did not single out specific violations or point to real world examples of misinformation.
“Although assessment of each promotional presentation involves a fact specific determination, representations or suggestions that create an impression that there are clinically meaningful differences between the reference product and its biosimilar, such as promotional presentations representing or suggesting that a reference product is safer or more effective than its biosimilar product, or that a biosimilar is safer or more effective than its reference product are likely to be false or misleading. Similarly, representations or suggestions that create an impression that a biosimilar is not highly similar to its reference product are likely to be false or misleading,” the 10-page draft guidance says.
Similarly, FDA says that companies claiming that a biosimilar is in general less safe or less effective than the reference product “simply because the biosimilar is licensed for fewer indications than the reference product would be misleading.”
Misleading comments were highlighted by Pfizer in August 2018, when it filed a citizen petition with FDA asking for help to combat comments that leave out important details about what a biosimilar is or that biosimilars work in the same way as reference products.
And Monday’s draft does reiterate that licensed biosimilars have “been found to be highly similar to the reference product notwithstanding minor differences in clinically inactive components and that there are no clinically meaningful differences between the biosimilar and the reference product in terms of safety, purity, and potency.” But the draft also does not discuss considerations unique to promotional materials for interchangeable biosimilars.
Novartis similarly raised issues with FDA in November 2018 about companies that seek “to foster fear and highlight hypothetical yet unproven risks associated with the use of FDA-approved biosimilars.” The Biosimilars Forum and others also sought to extinguish the ideas that biosimilars are somehow inferior products if they are not approved as interchangeable biosimilars, or to explain how the term “non-medical switching” is used “disingenuously to claim that transitioning from an originator to a biosimilar medicine is not safe.”
FDA’s draft also offers two examples of when it would not object to the promotions described, in addition to one example that would be considered misleading.
The misleading example discusses a statement that accurately conveys the reference product’s higher numeric overall response rates observed in a study, but that does not disclose that this difference in response rates was not statistically significant, and which fails to describe the study design or include other appropriate context.
In addition to the draft guidance, FDA and the Federal Trade Commission (FTC) also announced a public workshop on 9 March to discuss biosimilar competition.
The agencies said they will continue to exchange information about best practices to ensure biosimilar developers can gain access to samples of the reference product. The FTC also said it intends to review patent settlement agreements involving biosimilars to prevent antitrust violations.
Promotional Labeling and Advertising Considerations for Prescription Biological Reference and Biosimilar Products Questions and Answers Guidance for Industry
FDA´s Advice for Sponsors of Adaptive Design Clinical Trials
The FDA published a new guideline on Adaptive Design Clinical Trials for Drugs and Biologics. The document provides guidance to sponsors on the appropriate use of adaptive designs for clinical trials (CTs) to provide evidence of the effectiveness and safety of a drug or biologic. The guidance describes important principles for designing, conducting, and reporting the results from an adaptive CT. In addition, it advises sponsors on the types of information to submit to facilitate FDA evaluation. According to the agency, the concepts provided are also useful for early-phase or exploratory CTs as well as trials conducted to satisfy post-marketing requirements.
What is an Adaptive Design Clinical Trial?
The guidance defines an adaptive design as a CT design that allows for prospectively planned modifications to one or more aspects of the design based on accumulating data from subjects in the trial.
Potential Advantages
According to FDA, adaptive designs can provide a variety of advantages. These advantages arise from the fundamental property of CTs with an adaptive design: they allow to adjust the trial to information that was not available when the trial began. The specific nature of the advantages depends on the scientific context and type of adaptation considered, with the following potential advantages:
Statistical efficiency (i.e., greater statistical power),
Ethical advantages (e.g. the ability to stop a trial early if it becomes clear that the trial is unlikely to demonstrate effectiveness),
Improved understanding of drug effects,
Acceptability to stakeholders.
Data and Study Integrity
The FDA strongly recommends that access to comparative interim results be limited to individuals with relevant expertise who are independent of the personnel involved in conducting or managing the trial and have a need to know. It has to be ensured that patients, investigators and their staff as well as sponsors do not have access to comparative interim results. Knowledge of accumulating data by trial investigators can adversely affect patient accrual, adherence, retention, or endpoint assessment, compromising the ability of the trial to reliably achieve its objective in a timely manner. According to FDA, a clinical trial with an adaptive design should include the following:
A Data access plan that identifies who has access to confidential data, when that access occurs, and what types of data and results are involved.
Safeguards to ensure that the persons responsible for preparing and reporting interim analysis results are physically and logistically separated from the personnel tasked with managing and conducting the trial.
Limitation of access. In situations (such as dose selection) where limited access for specific sponsor personnel can be necessary, this limited access might be justifiable under certain circumstances. However, risks to trial integrity are most easily minimized by completely restricting sponsor access to comparative interim results.
Procedures to maintain and verify confidentiality, as well as documentation of monitoring and adherence to the operating procedures. Approaches typically include the use of confidentiality agreements for persons with access to interim data and the use of logistical or physical firewalls that prevent access by trial personnel to any data that include information that might allow one to infer treatment assignment.
Steps to minimize information that can be inferred by observers. Investigators and trial participants should be shielded as much as possible from knowledge of adaptive changes. For example, if the sample size is increased after an interim analysis, trial sites could be informed that the targeted enrollment number has not been reached rather than being notified of the specific targeted final sample size.
More information can be found in FDA´s Guidance for Industry: Adaptive Designs for Clinical Trials of Drugs and Biologics.
What is an Adaptive Design Clinical Trial?
The guidance defines an adaptive design as a CT design that allows for prospectively planned modifications to one or more aspects of the design based on accumulating data from subjects in the trial.
Potential Advantages
According to FDA, adaptive designs can provide a variety of advantages. These advantages arise from the fundamental property of CTs with an adaptive design: they allow to adjust the trial to information that was not available when the trial began. The specific nature of the advantages depends on the scientific context and type of adaptation considered, with the following potential advantages:
Statistical efficiency (i.e., greater statistical power),
Ethical advantages (e.g. the ability to stop a trial early if it becomes clear that the trial is unlikely to demonstrate effectiveness),
Improved understanding of drug effects,
Acceptability to stakeholders.
Data and Study Integrity
The FDA strongly recommends that access to comparative interim results be limited to individuals with relevant expertise who are independent of the personnel involved in conducting or managing the trial and have a need to know. It has to be ensured that patients, investigators and their staff as well as sponsors do not have access to comparative interim results. Knowledge of accumulating data by trial investigators can adversely affect patient accrual, adherence, retention, or endpoint assessment, compromising the ability of the trial to reliably achieve its objective in a timely manner. According to FDA, a clinical trial with an adaptive design should include the following:
A Data access plan that identifies who has access to confidential data, when that access occurs, and what types of data and results are involved.
Safeguards to ensure that the persons responsible for preparing and reporting interim analysis results are physically and logistically separated from the personnel tasked with managing and conducting the trial.
Limitation of access. In situations (such as dose selection) where limited access for specific sponsor personnel can be necessary, this limited access might be justifiable under certain circumstances. However, risks to trial integrity are most easily minimized by completely restricting sponsor access to comparative interim results.
Procedures to maintain and verify confidentiality, as well as documentation of monitoring and adherence to the operating procedures. Approaches typically include the use of confidentiality agreements for persons with access to interim data and the use of logistical or physical firewalls that prevent access by trial personnel to any data that include information that might allow one to infer treatment assignment.
Steps to minimize information that can be inferred by observers. Investigators and trial participants should be shielded as much as possible from knowledge of adaptive changes. For example, if the sample size is increased after an interim analysis, trial sites could be informed that the targeted enrollment number has not been reached rather than being notified of the specific targeted final sample size.
More information can be found in FDA´s Guidance for Industry: Adaptive Designs for Clinical Trials of Drugs and Biologics.
Warning Letter Issued to GPT Pharmaceuticals Private Ltd
This warning letter summarizes significant violations of current good manufacturing practice (CGMP) regulations for finished pharmaceuticals.
List of Drug Master Files (DMFs)
The list of DMFs, which is updated quarterly, contains DMFs received by December 31, 2019, for which acknowledgment letters were sent before January 8, 2020. The list is current through DMF 034489. Changes to the DMF activity status (A=active; I=inactive), DMF type, holder name, and subject (title) made since the last update of September 30, 2019, are included.
4Q2019 - All - Excel (XLS)
4Q2019 - All - Text (TXT)
4Q2019 - All - Excel (XLS)
4Q2019 - All - Text (TXT)
FDA Updates Compliance Guide on Pre-approval Inspections for Drugs
Drug manufacturers looking to avoid Form 483s take note: the US Food and Drug Administration (FDA) has recently tweaked its compliance guide on pre-approval inspections, which according to one consultant will impact analytical procedures and data included in regulatory submissions.
A pre-approval inspection is performed by FDA to ensure that a manufacturing establishment named in a drug application is capable of manufacturing a drug, and that submitted data are accurate and complete.
The front of the updated compliance guide, which was first released in September but which will not fully take effect until 16 September 2022, explains the changes: “Revision: Program revised to add instructions for potential official action indicated (pOAI) reporting responsibilities and to align with the Center for Drug Evaluation and Research (CDER) and Office of Regulatory Affairs (ORA) agreement Integration of FDA Facility Evaluation and Inspection Program for Human Drugs: A Concept of Operations.”
The 46-page guide also explains on its last page how the updates include redefined collaborations and shared responsibilities between CDER and ORA for determining and conducting an inspection, as well as updates to field reporting requirements, including updated instructions for pOAI reporting responsibilities.
And although the 2022 deadline may seem far away, the guide says the initial implementation date is 16 September 2019 and consultant R.D. McDowall explained in Spectroscopy how what's in the guide will likely be phased in over time and how “any analytical development work conducted that is part of a regulatory submission to the FDA” comes under this new version of the guide and, “Such work may be inspected against these more detailed requirements.”
The new guide also discusses its three objectives: 1: Readiness for Commercial Manufacturing (i.e., “Determine whether the establishment has a quality system that is designed to achieve sufficient control over the facility and commercial manufacturing operation”); 2: Conformance to Application (i.e., “Verify that the formulation, manufacturing or processing methods; analytical (or examination) methods; and batch records are consistent with descriptions contained in the CMC section of the application”); and 3: Data Integrity Audit (i.e. “Audit and verify raw data at the facility that are associated with the product.”).
For the third objective, McDowall notes that the guide now shows some indicators of possible laboratory data integrity problems. And if data are unreliable, the new version of the guide suggests that an inspector can expand the coverage of the inspection to marketed products under Compliance Program 7356.002 for Drug Manufacturing Inspections, or that FDA can invoke the Application Integrity Policy.
“If either of these occur, the laboratory has begun the long and very uncomfortable descent into inspection hell,” McDowall writes.
Revised Preapproval Inspection Compliance Guidance
A pre-approval inspection is performed by FDA to ensure that a manufacturing establishment named in a drug application is capable of manufacturing a drug, and that submitted data are accurate and complete.
The front of the updated compliance guide, which was first released in September but which will not fully take effect until 16 September 2022, explains the changes: “Revision: Program revised to add instructions for potential official action indicated (pOAI) reporting responsibilities and to align with the Center for Drug Evaluation and Research (CDER) and Office of Regulatory Affairs (ORA) agreement Integration of FDA Facility Evaluation and Inspection Program for Human Drugs: A Concept of Operations.”
The 46-page guide also explains on its last page how the updates include redefined collaborations and shared responsibilities between CDER and ORA for determining and conducting an inspection, as well as updates to field reporting requirements, including updated instructions for pOAI reporting responsibilities.
And although the 2022 deadline may seem far away, the guide says the initial implementation date is 16 September 2019 and consultant R.D. McDowall explained in Spectroscopy how what's in the guide will likely be phased in over time and how “any analytical development work conducted that is part of a regulatory submission to the FDA” comes under this new version of the guide and, “Such work may be inspected against these more detailed requirements.”
The new guide also discusses its three objectives: 1: Readiness for Commercial Manufacturing (i.e., “Determine whether the establishment has a quality system that is designed to achieve sufficient control over the facility and commercial manufacturing operation”); 2: Conformance to Application (i.e., “Verify that the formulation, manufacturing or processing methods; analytical (or examination) methods; and batch records are consistent with descriptions contained in the CMC section of the application”); and 3: Data Integrity Audit (i.e. “Audit and verify raw data at the facility that are associated with the product.”).
For the third objective, McDowall notes that the guide now shows some indicators of possible laboratory data integrity problems. And if data are unreliable, the new version of the guide suggests that an inspector can expand the coverage of the inspection to marketed products under Compliance Program 7356.002 for Drug Manufacturing Inspections, or that FDA can invoke the Application Integrity Policy.
“If either of these occur, the laboratory has begun the long and very uncomfortable descent into inspection hell,” McDowall writes.
Revised Preapproval Inspection Compliance Guidance
Bridging for Drug-Device and Biologic-Device Combination Products
This guidance provides recommendations to industry and FDA staff on how to approach bridging in new drug applications (NDAs) or biologics license applications (BLAs) for drug-device and biologic-device single entity or copackaged combination products including the following:
- Bridging of information related to a combination product that employs a different device constituent part or parts with the same drug constituent part or parts as the proposed combination product
- Bridging of information related to a combination product that employs a different drug constituent part or parts with the same device constituent part or parts as the proposed combination product
Subscribe to:
Posts (Atom)