Providing Regulatory Submissions in Electronic Format — Certain Human Pharmaceutical Product Applications and Related Submissions Using the eCTD Specifications Guidance for Industry
Under section 745A(a) of the Federal Food, Drug, and Cosmetic Act (FD&C Act), at least 24 months after the issuance of a final guidance document in which the Food and Drug Administration (FDA or Agency) has specified the electronic format for submitting submission types to the Agency, such content must be submitted electronically and in the format specified by FDA. , This guidance describes how sponsors and applicants must organize the content that they submit to the Agency electronically for all submission types under section 745A(a) of the FD&C Act. This guidance also references several technical specification documents and the Electronic Common Technical Document Conformance (eCTD) Guide, which provide additional details regarding the organization of content for electronic submissions. Under section 745A(a) of the Federal Food, Drug, and Cosmetic Act (FD&C Act), at least 24 months after the issuance of a final guidance document in which the Food and Drug Administration (FDA or Agency) has specified the electronic format for submitting submission types to the Agency, such content must be submitted electronically and in the format specified by FDA. , , This guidance describes how sponsors and applicants must organize the content that they submit to the Agency electronically for all submission types under section 745A(a) of the FD&C Act. This guidance also references several technical specification documents and the Electronic Common Technical Document Conformance (eCTD) Guide, which provide additional details regarding the organization of content for electronic submissions.
FDA Publishes Dataset of CDER Approvals Since 1985
To provide researchers with more accurate and accessible data about historic drug approvals, the US Food and Drug Administration (FDA) on Friday released a dataset containing information about all new drugs and biologics approved by the Center for Drug Evaluation and Research (CDER) dating back to 1985.
“FDA created the compilation to facilitate data accessibility, transparency, and accuracy when researchers seek information about an approved drug,” FDA writes, adding that the compilation should accurately reflect “the state of each application at the time of initial regulatory approval.”
The compilation itself is a downloadable .CSV file containing information on more than 1,000 new molecular entities (NMEs) and new biologics approved from 1 January 1985 through 31 December 2019.
For each product, the spreadsheet provides the proprietary name, active ingredient/moiety, applicant, application type, application number, dosage form, route of administration, receipt and approval dates, approved indications and uses, designations and whether a priority review voucher was issued or redeemed for the application.
Because the compilation is intended to provide information about products at the time of their original approval, some information, such as supplemental indications granted after the initial approval, are not included.
The agency says it will update the compilation periodically with new approval data, and asks that feedback and corrections be send to CDER.NMENewBiologicApprovals@fda.hhs.gov.
FDA has also published a “data dictionary” to accompany the compilation that provides a definition of each field included in the spreadsheet.
Read Details
“FDA created the compilation to facilitate data accessibility, transparency, and accuracy when researchers seek information about an approved drug,” FDA writes, adding that the compilation should accurately reflect “the state of each application at the time of initial regulatory approval.”
The compilation itself is a downloadable .CSV file containing information on more than 1,000 new molecular entities (NMEs) and new biologics approved from 1 January 1985 through 31 December 2019.
For each product, the spreadsheet provides the proprietary name, active ingredient/moiety, applicant, application type, application number, dosage form, route of administration, receipt and approval dates, approved indications and uses, designations and whether a priority review voucher was issued or redeemed for the application.
Because the compilation is intended to provide information about products at the time of their original approval, some information, such as supplemental indications granted after the initial approval, are not included.
The agency says it will update the compilation periodically with new approval data, and asks that feedback and corrections be send to CDER.NMENewBiologicApprovals@fda.hhs.gov.
FDA has also published a “data dictionary” to accompany the compilation that provides a definition of each field included in the spreadsheet.
Read Details
FDA Finalizes eCTD Guidance, Consults on eCTD v4.0 Technical Documents
The US Food and Drug Administration (FDA) on Friday finalized the seventh revision to its guidance on making regulatory submissions in electronic common technical document (eCTD) format to specify cases where an exemption or waiver from eCTD requirements is warranted.
The 17-page guidance finalizes a draft version released in July 2019 and replaces the previous final version from January 2019.
Within the guidance, FDA says it will exempt all Type III drug master files (DMFs) from eCTD requirements, in addition to noncommercial investigational new drugs (INDs).
The final guidance also clarifies that certain positron emission tomography (PET) drugs and Type II DMFs for PET drugs may qualify for a long-term waiver from eCTD requirements. Additionally, the final guidance explains the “unique and rare” circumstances in which the agency will grant short-term waivers from eCTD requirements, including events “beyond the control of the submitter,” such as natural disasters or malware attacks.
FDA also opened a public consultation on Friday for two eCTD technical documents, the eCTD v4.0 Technical Conformance Guidance and the FDA eCTD v4.0 Module 1 Implementation Package.
The eCTD Technical Conformance Guide is meant to provide drugmakers with “specification, recommendations, and general considerations” for filing eCTD v4.0-based submissions with the Center for Drug Evaluation and Research (CDER) and Center for Biologics Evaluation and Research (CBER) using either the International Council for Harmonisation or FDA implementation packages.
FDA says it is looking for comments to ensure the “accuracy, suitability, and appropriateness of these specifications for the submission of eCTD v4.0 submissions,” and notes that the documents are not meant for implementation at this time and that the agency will “only accept eCTD v3.2.2 submissions” until v4.0 is finalized.
Read on FDA website
The 17-page guidance finalizes a draft version released in July 2019 and replaces the previous final version from January 2019.
Within the guidance, FDA says it will exempt all Type III drug master files (DMFs) from eCTD requirements, in addition to noncommercial investigational new drugs (INDs).
The final guidance also clarifies that certain positron emission tomography (PET) drugs and Type II DMFs for PET drugs may qualify for a long-term waiver from eCTD requirements. Additionally, the final guidance explains the “unique and rare” circumstances in which the agency will grant short-term waivers from eCTD requirements, including events “beyond the control of the submitter,” such as natural disasters or malware attacks.
FDA also opened a public consultation on Friday for two eCTD technical documents, the eCTD v4.0 Technical Conformance Guidance and the FDA eCTD v4.0 Module 1 Implementation Package.
The eCTD Technical Conformance Guide is meant to provide drugmakers with “specification, recommendations, and general considerations” for filing eCTD v4.0-based submissions with the Center for Drug Evaluation and Research (CDER) and Center for Biologics Evaluation and Research (CBER) using either the International Council for Harmonisation or FDA implementation packages.
FDA says it is looking for comments to ensure the “accuracy, suitability, and appropriateness of these specifications for the submission of eCTD v4.0 submissions,” and notes that the documents are not meant for implementation at this time and that the agency will “only accept eCTD v3.2.2 submissions” until v4.0 is finalized.
Read on FDA website
FDA Consolidates Nonclinical Immunotoxicity Evaluation Guidance
The US Food and Drug Administration (FDA) on Wednesday issued a new draft guidance consolidating its recommendations on nonclinical safety evaluations for immunotoxicity and withdrew an earlier 2002 guidance on the topic.
FDA says the guidance addresses issues related to evaluating immunotoxicity including immune suppression, modulation and stimulation and provides recommendations for carcinogenicity assessments, dermal sensitization, adjuvanted vaccine development and developmental and juvenile animal studies.
The 10-page draft guidance consolidates and supplements recommendations from various guidances, including the International Council for Harmonisation (ICH) S8 Immunotoxicity Studies for Human Pharmaceuticals guideline and FDA’s 2006 guidance Considerations for Developmental Toxicity Studies for Preventive and Therapeutic Vaccines for Infectious Disease Indications.
FDA says the guidance applies to new drugs, therapeutic proteins and recombinant/plasma-derived blood proteins regulated by the Center for Drug Evaluation and Research (CDER) and the Center for Biologics Evaluation and Research (CBER) but does not apply to cell and gene therapies, adjuvanted vaccines or other types of biologics.
“The extent of the effects on the immune system should be adequately characterized to properly inform the overall risk-benefit of the product,” FDA writes.
FDA also reminds sponsors to, “to the extent practicable, follow existing guidance on placing immunotoxicology studies in the electronic common technical document (eCTD) format.”
The guidance is broken up into three main sections, the first two discuss approaches to assessing the potential for products to reduce or increase immune system activity, while the third section provides considerations for developmental and juvenile animal studies.
FDA says the guidance addresses issues related to evaluating immunotoxicity including immune suppression, modulation and stimulation and provides recommendations for carcinogenicity assessments, dermal sensitization, adjuvanted vaccine development and developmental and juvenile animal studies.
The 10-page draft guidance consolidates and supplements recommendations from various guidances, including the International Council for Harmonisation (ICH) S8 Immunotoxicity Studies for Human Pharmaceuticals guideline and FDA’s 2006 guidance Considerations for Developmental Toxicity Studies for Preventive and Therapeutic Vaccines for Infectious Disease Indications.
FDA says the guidance applies to new drugs, therapeutic proteins and recombinant/plasma-derived blood proteins regulated by the Center for Drug Evaluation and Research (CDER) and the Center for Biologics Evaluation and Research (CBER) but does not apply to cell and gene therapies, adjuvanted vaccines or other types of biologics.
“The extent of the effects on the immune system should be adequately characterized to properly inform the overall risk-benefit of the product,” FDA writes.
FDA also reminds sponsors to, “to the extent practicable, follow existing guidance on placing immunotoxicology studies in the electronic common technical document (eCTD) format.”
The guidance is broken up into three main sections, the first two discuss approaches to assessing the potential for products to reduce or increase immune system activity, while the third section provides considerations for developmental and juvenile animal studies.
Second Revision of FDA Guidance Microbiology Data for Systemic Antibacterial Drugs
In February, the FDA published the second revision of their Guidance for Industry "Microbiology Data for Systemic Antibacterial Drugs -Development, Analysis, and Presentation". The focus of that guidance document is on assisting sponsors in the development, analysis, and presentation of microbiology data during antibacterial drug development. It replaces the guidance for industry "Microbiology Data for Systemic Antibacterial Drugs - Development, Analysis, and Presentation" issued in August 2016.
In the document the FDA defines their expectation on a microbiology development programme needed to support clinical development and approval of antibacterial drugs administered systemically as well as microbiology information collected after approval.
The current guideline covers the following topics:
I. INTRODUCTION
II. MICROBIOLOGY DEVELOPMENT PROGRAM
A. Early Development Nonclinical Considerations
1. Antibacterial Spectrum of Activity
2. Mechanism of Action
3. Intracellular Antimicrobial Concentration Assessment
4. Resistance Studies
B. In Vitro Antimicrobial Susceptibility Test Methods During Drug Development
1. Early Clinical Development
2. Provisional Antibacterial Susceptibility Test Interpretive Criteria
3. Establishing In Vitro Antibacterial Susceptibility Test Interpretive Criteria
4. Quality Control Parameters
C. Other Considerations
1. First and Second Lists of Target Bacteria in Labeling
2. Antibacterial Interactions and Fixed-Combination Studies
3. Additional Nonclinical Studies of Antibacterial Drugs
4. Animal Models of Infection
5. Microbiology Information Collected in Clinical Trials
6. Electronic Submission of Microbiology Information
7. Location of Microbiology Information
8. Postmarketing Microbiology Information
Additionally the following appendizes are part of the revised guideline:
APPENDIX A: GUIDELINES FOR BACTERIAL ISOLATE SELECTION FOR STUDIES OF IN VITRO ANTIBACTERIAL ACTIVITY
APPENDIX B: STUDY REPORTS OF SPECTRUM OF ACTIVITY AND RESISTANCE
APPENDIX C: DATABASE FOR FINAL IN VITRO ANTIBACTERIAL SUSCEPTIBILITY TEST INTERPRETIVE CRITERIA
APPENDIX D: EXAMPLE FORMAT FOR SECTIONS OF LABELING THAT PERTAIN TO MICROBIOLOGY
APPENDIX E: INFORMATION REGARDING THE SECOND BACTERIA LIST IN THE MICROBIOLOGY SUBSECTION OF LABELING
This guidance addresses the types of microbiology information that should be provided to support an investigational new drug application (IND), a new drug application (INDA), a biologics license application (BLA), and a supplemental NDA or BLA. For more details see the full document "Microbiology Data for Systemic Antibacterial Drugs"
In the document the FDA defines their expectation on a microbiology development programme needed to support clinical development and approval of antibacterial drugs administered systemically as well as microbiology information collected after approval.
The current guideline covers the following topics:
I. INTRODUCTION
II. MICROBIOLOGY DEVELOPMENT PROGRAM
A. Early Development Nonclinical Considerations
1. Antibacterial Spectrum of Activity
2. Mechanism of Action
3. Intracellular Antimicrobial Concentration Assessment
4. Resistance Studies
B. In Vitro Antimicrobial Susceptibility Test Methods During Drug Development
1. Early Clinical Development
2. Provisional Antibacterial Susceptibility Test Interpretive Criteria
3. Establishing In Vitro Antibacterial Susceptibility Test Interpretive Criteria
4. Quality Control Parameters
C. Other Considerations
1. First and Second Lists of Target Bacteria in Labeling
2. Antibacterial Interactions and Fixed-Combination Studies
3. Additional Nonclinical Studies of Antibacterial Drugs
4. Animal Models of Infection
5. Microbiology Information Collected in Clinical Trials
6. Electronic Submission of Microbiology Information
7. Location of Microbiology Information
8. Postmarketing Microbiology Information
Additionally the following appendizes are part of the revised guideline:
APPENDIX A: GUIDELINES FOR BACTERIAL ISOLATE SELECTION FOR STUDIES OF IN VITRO ANTIBACTERIAL ACTIVITY
APPENDIX B: STUDY REPORTS OF SPECTRUM OF ACTIVITY AND RESISTANCE
APPENDIX C: DATABASE FOR FINAL IN VITRO ANTIBACTERIAL SUSCEPTIBILITY TEST INTERPRETIVE CRITERIA
APPENDIX D: EXAMPLE FORMAT FOR SECTIONS OF LABELING THAT PERTAIN TO MICROBIOLOGY
APPENDIX E: INFORMATION REGARDING THE SECOND BACTERIA LIST IN THE MICROBIOLOGY SUBSECTION OF LABELING
This guidance addresses the types of microbiology information that should be provided to support an investigational new drug application (IND), a new drug application (INDA), a biologics license application (BLA), and a supplemental NDA or BLA. For more details see the full document "Microbiology Data for Systemic Antibacterial Drugs"
Biologic and Biosimilar Misinformation: FDA Drafts Guidance
Since at least 2018, various industry groups and biopharma companies have highlighted the ways that the truth has been stretched around biosimilars and their reference products, and they have sought help from the US Food and Drug Administration (FDA) in setting the record straight.
FDA on Monday offered some help in the way of a new draft guidance, with eight questions and answers explaining how companies can promote reference or biosimilar products in truthful and non-misleading ways. But the agency did not single out specific violations or point to real world examples of misinformation.
“Although assessment of each promotional presentation involves a fact specific determination, representations or suggestions that create an impression that there are clinically meaningful differences between the reference product and its biosimilar, such as promotional presentations representing or suggesting that a reference product is safer or more effective than its biosimilar product, or that a biosimilar is safer or more effective than its reference product are likely to be false or misleading. Similarly, representations or suggestions that create an impression that a biosimilar is not highly similar to its reference product are likely to be false or misleading,” the 10-page draft guidance says.
Similarly, FDA says that companies claiming that a biosimilar is in general less safe or less effective than the reference product “simply because the biosimilar is licensed for fewer indications than the reference product would be misleading.”
Misleading comments were highlighted by Pfizer in August 2018, when it filed a citizen petition with FDA asking for help to combat comments that leave out important details about what a biosimilar is or that biosimilars work in the same way as reference products.
And Monday’s draft does reiterate that licensed biosimilars have “been found to be highly similar to the reference product notwithstanding minor differences in clinically inactive components and that there are no clinically meaningful differences between the biosimilar and the reference product in terms of safety, purity, and potency.” But the draft also does not discuss considerations unique to promotional materials for interchangeable biosimilars.
Novartis similarly raised issues with FDA in November 2018 about companies that seek “to foster fear and highlight hypothetical yet unproven risks associated with the use of FDA-approved biosimilars.” The Biosimilars Forum and others also sought to extinguish the ideas that biosimilars are somehow inferior products if they are not approved as interchangeable biosimilars, or to explain how the term “non-medical switching” is used “disingenuously to claim that transitioning from an originator to a biosimilar medicine is not safe.”
FDA’s draft also offers two examples of when it would not object to the promotions described, in addition to one example that would be considered misleading.
The misleading example discusses a statement that accurately conveys the reference product’s higher numeric overall response rates observed in a study, but that does not disclose that this difference in response rates was not statistically significant, and which fails to describe the study design or include other appropriate context.
In addition to the draft guidance, FDA and the Federal Trade Commission (FTC) also announced a public workshop on 9 March to discuss biosimilar competition.
The agencies said they will continue to exchange information about best practices to ensure biosimilar developers can gain access to samples of the reference product. The FTC also said it intends to review patent settlement agreements involving biosimilars to prevent antitrust violations.
Promotional Labeling and Advertising Considerations for Prescription Biological Reference and Biosimilar Products Questions and Answers Guidance for Industry
FDA on Monday offered some help in the way of a new draft guidance, with eight questions and answers explaining how companies can promote reference or biosimilar products in truthful and non-misleading ways. But the agency did not single out specific violations or point to real world examples of misinformation.
“Although assessment of each promotional presentation involves a fact specific determination, representations or suggestions that create an impression that there are clinically meaningful differences between the reference product and its biosimilar, such as promotional presentations representing or suggesting that a reference product is safer or more effective than its biosimilar product, or that a biosimilar is safer or more effective than its reference product are likely to be false or misleading. Similarly, representations or suggestions that create an impression that a biosimilar is not highly similar to its reference product are likely to be false or misleading,” the 10-page draft guidance says.
Similarly, FDA says that companies claiming that a biosimilar is in general less safe or less effective than the reference product “simply because the biosimilar is licensed for fewer indications than the reference product would be misleading.”
Misleading comments were highlighted by Pfizer in August 2018, when it filed a citizen petition with FDA asking for help to combat comments that leave out important details about what a biosimilar is or that biosimilars work in the same way as reference products.
And Monday’s draft does reiterate that licensed biosimilars have “been found to be highly similar to the reference product notwithstanding minor differences in clinically inactive components and that there are no clinically meaningful differences between the biosimilar and the reference product in terms of safety, purity, and potency.” But the draft also does not discuss considerations unique to promotional materials for interchangeable biosimilars.
Novartis similarly raised issues with FDA in November 2018 about companies that seek “to foster fear and highlight hypothetical yet unproven risks associated with the use of FDA-approved biosimilars.” The Biosimilars Forum and others also sought to extinguish the ideas that biosimilars are somehow inferior products if they are not approved as interchangeable biosimilars, or to explain how the term “non-medical switching” is used “disingenuously to claim that transitioning from an originator to a biosimilar medicine is not safe.”
FDA’s draft also offers two examples of when it would not object to the promotions described, in addition to one example that would be considered misleading.
The misleading example discusses a statement that accurately conveys the reference product’s higher numeric overall response rates observed in a study, but that does not disclose that this difference in response rates was not statistically significant, and which fails to describe the study design or include other appropriate context.
In addition to the draft guidance, FDA and the Federal Trade Commission (FTC) also announced a public workshop on 9 March to discuss biosimilar competition.
The agencies said they will continue to exchange information about best practices to ensure biosimilar developers can gain access to samples of the reference product. The FTC also said it intends to review patent settlement agreements involving biosimilars to prevent antitrust violations.
Promotional Labeling and Advertising Considerations for Prescription Biological Reference and Biosimilar Products Questions and Answers Guidance for Industry
FDA´s Advice for Sponsors of Adaptive Design Clinical Trials
The FDA published a new guideline on Adaptive Design Clinical Trials for Drugs and Biologics. The document provides guidance to sponsors on the appropriate use of adaptive designs for clinical trials (CTs) to provide evidence of the effectiveness and safety of a drug or biologic. The guidance describes important principles for designing, conducting, and reporting the results from an adaptive CT. In addition, it advises sponsors on the types of information to submit to facilitate FDA evaluation. According to the agency, the concepts provided are also useful for early-phase or exploratory CTs as well as trials conducted to satisfy post-marketing requirements.
What is an Adaptive Design Clinical Trial?
The guidance defines an adaptive design as a CT design that allows for prospectively planned modifications to one or more aspects of the design based on accumulating data from subjects in the trial.
Potential Advantages
According to FDA, adaptive designs can provide a variety of advantages. These advantages arise from the fundamental property of CTs with an adaptive design: they allow to adjust the trial to information that was not available when the trial began. The specific nature of the advantages depends on the scientific context and type of adaptation considered, with the following potential advantages:
Statistical efficiency (i.e., greater statistical power),
Ethical advantages (e.g. the ability to stop a trial early if it becomes clear that the trial is unlikely to demonstrate effectiveness),
Improved understanding of drug effects,
Acceptability to stakeholders.
Data and Study Integrity
The FDA strongly recommends that access to comparative interim results be limited to individuals with relevant expertise who are independent of the personnel involved in conducting or managing the trial and have a need to know. It has to be ensured that patients, investigators and their staff as well as sponsors do not have access to comparative interim results. Knowledge of accumulating data by trial investigators can adversely affect patient accrual, adherence, retention, or endpoint assessment, compromising the ability of the trial to reliably achieve its objective in a timely manner. According to FDA, a clinical trial with an adaptive design should include the following:
A Data access plan that identifies who has access to confidential data, when that access occurs, and what types of data and results are involved.
Safeguards to ensure that the persons responsible for preparing and reporting interim analysis results are physically and logistically separated from the personnel tasked with managing and conducting the trial.
Limitation of access. In situations (such as dose selection) where limited access for specific sponsor personnel can be necessary, this limited access might be justifiable under certain circumstances. However, risks to trial integrity are most easily minimized by completely restricting sponsor access to comparative interim results.
Procedures to maintain and verify confidentiality, as well as documentation of monitoring and adherence to the operating procedures. Approaches typically include the use of confidentiality agreements for persons with access to interim data and the use of logistical or physical firewalls that prevent access by trial personnel to any data that include information that might allow one to infer treatment assignment.
Steps to minimize information that can be inferred by observers. Investigators and trial participants should be shielded as much as possible from knowledge of adaptive changes. For example, if the sample size is increased after an interim analysis, trial sites could be informed that the targeted enrollment number has not been reached rather than being notified of the specific targeted final sample size.
More information can be found in FDA´s Guidance for Industry: Adaptive Designs for Clinical Trials of Drugs and Biologics.
What is an Adaptive Design Clinical Trial?
The guidance defines an adaptive design as a CT design that allows for prospectively planned modifications to one or more aspects of the design based on accumulating data from subjects in the trial.
Potential Advantages
According to FDA, adaptive designs can provide a variety of advantages. These advantages arise from the fundamental property of CTs with an adaptive design: they allow to adjust the trial to information that was not available when the trial began. The specific nature of the advantages depends on the scientific context and type of adaptation considered, with the following potential advantages:
Statistical efficiency (i.e., greater statistical power),
Ethical advantages (e.g. the ability to stop a trial early if it becomes clear that the trial is unlikely to demonstrate effectiveness),
Improved understanding of drug effects,
Acceptability to stakeholders.
Data and Study Integrity
The FDA strongly recommends that access to comparative interim results be limited to individuals with relevant expertise who are independent of the personnel involved in conducting or managing the trial and have a need to know. It has to be ensured that patients, investigators and their staff as well as sponsors do not have access to comparative interim results. Knowledge of accumulating data by trial investigators can adversely affect patient accrual, adherence, retention, or endpoint assessment, compromising the ability of the trial to reliably achieve its objective in a timely manner. According to FDA, a clinical trial with an adaptive design should include the following:
A Data access plan that identifies who has access to confidential data, when that access occurs, and what types of data and results are involved.
Safeguards to ensure that the persons responsible for preparing and reporting interim analysis results are physically and logistically separated from the personnel tasked with managing and conducting the trial.
Limitation of access. In situations (such as dose selection) where limited access for specific sponsor personnel can be necessary, this limited access might be justifiable under certain circumstances. However, risks to trial integrity are most easily minimized by completely restricting sponsor access to comparative interim results.
Procedures to maintain and verify confidentiality, as well as documentation of monitoring and adherence to the operating procedures. Approaches typically include the use of confidentiality agreements for persons with access to interim data and the use of logistical or physical firewalls that prevent access by trial personnel to any data that include information that might allow one to infer treatment assignment.
Steps to minimize information that can be inferred by observers. Investigators and trial participants should be shielded as much as possible from knowledge of adaptive changes. For example, if the sample size is increased after an interim analysis, trial sites could be informed that the targeted enrollment number has not been reached rather than being notified of the specific targeted final sample size.
More information can be found in FDA´s Guidance for Industry: Adaptive Designs for Clinical Trials of Drugs and Biologics.
Subscribe to:
Posts (Atom)